Acoustic Plaster System London

Posted on 2 August 2023

Pacy & Wheatley Acoustics is pleased to announce that we have successfully completed another acoustic ceiling installation. The project saw the team install the advanced Rockfon Mono Acoustic plaster system in Stephenson House, a large building close to Euston Station. The building, a mixture of residential and commercial properties, was undergoing renovations led by principal contractor 8Build. Pacy & Wheatley Acoustics was hired to bring their sound acoustics expertise to the project. In the end, we installed more than 650m2 of Rockfon Mono plaster in the reception, cafe, and numerous lobbies.

Overcoming Challenges

As you might expect from such a large and ambitious project, there were challenges.

The biggest challenge was having to work around light fixtures, 150 hanging rods, and ventilation systems. But challenges are there to be overcome, and the team is pleased to report that we were able to find solutions without experiencing any major project delays.

A Successful Outcome

We like to know that we did a good job, but what really counts is the view of our clients. Happily, they were as thrilled as we were, and we hope that this marks the beginning of a long working relationship.

Contact Pacy & Wheatley Acoustics Today

If you're in need of any help with the acoustics in your building, then don't hesitate to get in touch with us here at Pacy Wheatley Acoustics. As the leading experts in our field, we've helped some of the biggest brands in the world find the acoustic solution they need, and we're confident that we can help you with whatever acoustic optimisation you need.

eBook Cover

    Download Our

    Flip eBrochure

    Please enter your name and email to access our company eBrochure.

    Please view our Privacy Policy for more information on how we use your data.

    Old Boy

    Dimensions & weight

    3mm: 3 mm (1/8 inch) thick. Weight (dry) 0.7 kg/m² (2,2 oz/ft²).

    25 mm: 28 mm (1,1 inch) total construction height. Weight (dry, excl adhesive/mech. fasteners) 3.55 kg/m² (11,6 oz/ft²).

    39 mm: 42 mm (1,65 inch) total construction height. Weight (dry, excl adhesive/mech. fasteners) 4.7 kg/m² (15,4 oz/ft²).

    Installation

    3 mm: Can be mounted on walls or ceilings. On flat or vaulted surfaces. On most absorbent surfaces, primer may sometimes be needed.

    25 mm-39 mm: Can be mounted on walls or ceilings. On flat or vaulted surfaces. Can be mounted with no gaps on existing ceilings or wall surfaces, suspended mounted on plasterboard or suspended directly from a track system.

    Light reflectance

    3 mm-39 mm: 90,0% per ASTM E1477-98a.

    Fire safety classification

    3 mm-39 mm: Class A per ASTM E84; B s1d0 per ISO EN 13823.

    Cleaning and repair

    Can be vacuumed. Spots can be removed with water and sponge. Damaged surfaces can be repaired.

    Environment

    3 mm-39 mm: 4 g/l (0,03 lbs/gal) VOC (emissions) per ASTM D3960, LEED.

    Climate

    Installation temperatures should be between 15 °C and 32 °C (60 °F and 90 °F) with humidity that does not exceed 70%. Tested for mold growth per ASTM D3273.

    Sound absorption

    25 mm: NRC 0.75-0.80 per ASTM C423. Alpha W 0,85 (class B) per ISO 354/ISO11654.

    39 mm: NRC 0.80-0.90 per ASTM C423. Alpha W 0.90-0,95 (class A) per ISO 354/ISO11654.

    Straight Up

    Dimensions & weight

    25 mm: 26 mm (1 1/32 inch) total construction height. Weight (dry, excl adhesive/mech. fasteners) 2.78 kg/m² (9.11 oz/ft²).

    39 mm: 40 mm (1 37/64 inch) total construction height. Weight (dry, excl adhesive/mech. fasteners) 4.12 kg/m² (13.51 oz/ft²).

    Installation

    25 mm-39 mm: Can be mounted on walls or ceilings. Can be mounted with no gaps on existing ceilings or wall surfaces, suspended mounted on plasterboard or suspended directly from a track system.

    Light reflectance

    93% per ASTM E147-98A.

    Fire safety classification

    25 mm-39 mm: Class A per ASTM E84, A2 s1d0 per ISO EN-13501-1:2018

    Cleaning and repair

    Can be vacuumed. Spots can be removed with water and sponge. Damaged surfaces can be repaired.

    Color selection

    Can be tinted in the entire NCS, RAL, Sherwin Williams or Benjamin Moore color scale.

    Environment

    25 mm-39 mm: 0 g/l (0,00 lbs/gal) VOC (emissions) per ASTM D3960, LEED.

    Climate

    Installation temperatures should be between 15 °C and 32 °C (60 °F and 90 °F) with humidity that does not exceed 70%. Tested for mold growth per ASTM D3273.

    Sound absorption

    25 mm: NRC 0.85-0.90 per ASTM C423. Alpha W 0.85 (class B)-0.95 (class A) per ISO 354/ISO11654.

    39 mm: NRC 0.85-0.90 per ASTM C423. Alpha W 0,90 – 0.95 (class A) per ISO 354/ISO11654.

    Stone Greyhound

    Dimensions & weight

    3 mm: 3 mm (1/8 inch) thick. Weight (dry) 0.7 kg/m² (2,2 oz/ft²).

    25 mm: 28 mm (1,1 inch) total construction height. Weight (dry, excl. adhesive/mech. fasteners) 3.55 kg/m² (11,6 oz/ft²).

    39 mm: 42 mm (1,65 inch) total construction height. Weight (dry, excl. adhesive/mech. fasteners) 4.7 kg/m² (15,4 oz/ft²).

    Installation

    3 mm: Can be mounted on walls or ceilings. On flat or vaulted surfaces. On most absorbent surfaces, primer may sometimes be needed.

    25 mm-39 mm: Can be mounted on walls or ceilings. On flat or vaulted surfaces. Can be mounted with no gaps on existing ceilings or wall surfaces, suspended mounted on plasterboard or suspended directly from a track system.

    Light reflectance

    3 mm-39 mm: 90,0% per ASTM E1477-98a.

    Fire safety classification

    3 mm-39 mm: Class A per ASTM E84; B s1d0 per ISO EN 13823.

    Cleaning and repair

    Can be vacuumed. Spots can be removed with water and sponge. Damaged surfaces can be repaired.

    Environment

    3 mm-39 mm: 4 g/l (0,03 lbs/gal) VOC (emissions) per ASTM D3960, LEED.

    Climate

    Installation temperatures should be between 15 °C and 32 °C (60 °F and 90 °F) with humidity that does not exceed 70%. Tested for mold growth per ASTM D3273.

    Sound absorption

    25 mm: NRC 0.45-0.60 per ASTM C423. Alpha W 0,50 (class D)-0,55 (class D) per ISO 354/ISO11654.

    39 mm: NRC 0.50-0.60 per ASTM C423. Alpha W 0,55 (class D) per ISO 354/ISO11654.

    Silk White

    Dimensions & weight

    3 mm (1/8 inch) thick. Weight (dry) 0.7 kg/m² (2,2 oz/ft²).

    25 mm: 28 mm (1,1 inch) total construction height. Weight (dry, excl adhesive/mech. fasteners) 3.55 kg/m² (11,6 oz/ft²).

    39 mm: 42 mm (1,65 inch) total construction height. Weight (dry, excl adhesive/mech. fasteners) 4.7 kg/m² (15,4 oz/ft²).

    Installation

    3 mm: Can be mounted on walls or ceilings. On flat or vaulted surfaces. On most absorbent surfaces, primer may sometimes be needed.

    25 mm-39 mm: Can be mounted on walls or ceilings. On flat or vaulted surfaces. Can be mounted with no gaps on existing ceilings or wall surfaces, suspended mounted on plasterboard or suspended directly from a track system.

    Light reflectance

    90,0% per ASTM E147-98A.

    Fire safety classification

    3 mm-39 mm: Class A per ASTM E84; B s1d0 per ISO EN 13823.

    Cleaning and repair

    Can be vacuumed. Spots can be removed with water and sponge. Damaged surfaces can be repaired.

    Color selection

    Can be tinted in the entire NCS, RAL, Sherwin Williams or Benjamin Moore color scale.

    Environment

    3 mm-39 mm: 4 g/l (0,03 lbs/gal) VOC (emissions) per ASTM D3960, LEED.

    Climate

    Installation temperatures should be between 15 °C and 32 °C (60 °F and 90 °F) with humidity that does not exceed 70%. Tested for mold growth per ASTM D3273.

    Sound absorption

    3 mm: NRC 0.30 per ASTM C423, Alpha W 0.35 (class D).

    25 mm: NRC 0.81-0.85 per ASTM C423. Alpha W 0,85 (class B)-0,90 (class A) per ISO 354/ISO11654.

    39 mm: NRC 0.90 per ASTM C423. Alpha W 0,95 – 1,00 (class A) per ISO 354/ISO11654.

    Silk Metallic Gold

    Dimensions & weight

    3 mm (1/8 inch) thick. Weight (dry) 0.7 kg/m² (2,2 oz/ft²).

    25 mm: 28 mm (1,1 inch) total construction height. Weight (dry, excl adhesive/mech. fasteners) 3.55 kg/m² (11,6 oz/ft²).

    39 mm: 42 mm (1,65 inch) total construction height. Weight (dry, excl adhesive/mech. fasteners) 4.7 kg/m² (15,4 oz/ft²).

    Installation

    3 mm: Can be mounted on walls or ceilings. On flat or vaulted surfaces. On most absorbent surfaces, primer may sometimes be needed.

    25 mm-39 mm: Can be mounted on walls or ceilings. On flat or vaulted surfaces. Can be mounted with no gaps on existing ceilings or wall surfaces, suspended mounted on plasterboard or suspended directly from a track system.

    Fire safety classification

    3 mm-39 mm: Class A per ASTM E84; B s1d0 per ISO EN 13823.

    Cleaning and repair

    Can be vacuumed. Spots can be removed with water and sponge. Damaged surfaces can be repaired.

    Environment

    3 mm-39 mm: 4 g/l (0,03 lbs/gal) VOC (emissions) per ASTM D3960, LEED.

    Climate

    Installation temperatures should be between 15 °C and 32 °C (60 °F and 90 °F) with humidity that does not exceed 70%. Tested for mold growth per ASTM D3273.

    Sound absorption

    25 mm: NRC 0.75-0.85 enl. ASTM C423. Alpha W 0.70 (class C)-0.85 (class B) per ISO 354/ISO11654.

    39 mm: NRC 0.80-0.85 per ASTM C423. Alpha W 0.85 (class B) – 0.90 (class A) enl. ISO 354/ISO11654

    Secern

    Dimensions & weight

    3 mm (1/8 inch) thick. Weight (dry) 0.7 kg/m² (2,2 oz/ft²).

    25 mm: 28 mm (1,1 inch) total construction height. Weight (dry, excl. adhesive/mech. fasteners) 3.55 kg/m² (11,6 oz/ft²).

    39 mm: 42 mm (1,65 inch) total construction height. Weight (dry, excl adhesive/mech. fasteners) 4.7 kg/m² (15,4 oz/ft²).

    Installation

    3 mm: Can be mounted on walls or ceilings. On flat or vaulted surfaces. On most absorbent surfaces, primer may sometimes be needed.

    25 mm-39 mm: Can be mounted on walls or ceilings. On flat or vaulted surfaces. Can be mounted with no gaps on existing ceilings or wall surfaces, suspended mounted on plasterboard or suspended directly from a track system.

    Light reflectance

    3 mm-39 mm: 90,0% per ASTM E1477-98a.

    Fire safety classification

    3 mm-39 mm: Class A per ASTM E84; B s1d0 per ISO EN 13823.

    Cleaning and repair

    Can be vacuumed. Spots can be removed with water and sponge. Damaged surfaces can be repaired.

    Color selection

    Can be tinted in the entire NCS, RAL, Sherwin Williams or Benjamin Moore color scale.

    Environment

    3 mm-39 mm: 4 g/l (0,03 lbs/gal) VOC (emissions) per ASTM D3960, LEED.

    Climate

    Installation temperatures should be between 15 °C and 32 °C (60 °F and 90 °F) with humidity that does not exceed 70%. Tested for mold growth per ASTM D3273.

    Sound absorption

    3 mm: NRC 0.30 per ASTM C423.

    25 mm: NRC 0.75-0.80 per ASTM C423. Alpha W 0,80 (class B) per ISO 354/ISO11654.

    39 mm: NRC 0.85-0.90 per ASTM C423. Alpha W 0,95 (class A) per ISO 354/ISO11654.

    Sahara

    Dimensions & weight

    3 mm (1/8 inch) thick. Weight (dry) 0.7 kg/m² (2,2 oz/ft²).

    25 mm: 28 mm (1,1 inch) total construction height. Weight (dry, excl adhesive/mech. fasteners) 3.55 kg/m² (11,6 oz/ft²).

    39 mm: 42 mm (1,65 inch) total construction height. Weight (dry, excl adhesive/mech. fasteners) 4.7 kg/m² (15,4 oz/ft²).

    Installation

    3 mm: Can be mounted on walls or ceilings. On flat or vaulted surfaces. On most absorbent surfaces, primer may sometimes be needed.

    25 mm-39 mm: Can be mounted on walls or ceilings. On flat or vaulted surfaces. Can be mounted with no gaps on existing ceilings or wall surfaces, suspended mounted on plasterboard or suspended directly from a track system.

    Light reflectance

    3 mm-39 mm: 90,0% per ASTM E1477-98a.

    Fire safety classification

    3 mm-39 mm: Class A per ASTM E84; B s1d0 per ISO EN 13823.

    Cleaning and repair

    Can be vacuumed. Spots can be removed with water and sponge. Damaged surfaces can be repaired.

    Color selection

    Can be tinted in the entire NCS, RAL, Sherwin Williams or Benjamin Moore color scale.

    Environment

    3 mm-39 mm: 4 g/l (0,03 lbs/gal) VOC (emissions) per ASTM D3960, LEED.

    Climate

    Installation temperatures should be between 15 °C and 32 °C (60 °F and 90 °F) with humidity that does not exceed 70%. Tested for mold growth per ASTM D3273.

    Sound absorption

    3 mm: NRC 0.30 per ASTM C423. Alpha W 0.35 (class D)

    25 mm: NRC 0.70-0.80 per ASTM C423. Alpha W 0,75 (class C)-0,90 (class A) per ISO 354/ISO11654.

    39 mm: NRC 0.90-0.95 per ASTM C423. Alpha W 0,95 – 1,00 (class A) per ISO 354/ISO11654.

    New England

    Dimensions & weight

    3 mm: 3 mm (1/8 inch) thick. Weight (dry) 0.7 kg/m² (2,2 oz/ft²).

    25 mm: 28 mm (1,1 inch) total construction height. Weight (dry, excl adhesive/mech. fasteners) 3.55 kg/m² (11,6 oz/ft²).

    39 mm: 42 mm (1,65 inch) total construction height. Weight (dry, excl adhesive/mech. fasteners) 4.7 kg/m² (15,4 oz/ft²).

    Installation

    3 mm: Can be mounted on walls or ceilings. On flat or vaulted surfaces. On most absorbent surfaces, primer may sometimes be needed.

    25 mm-39 mm: Can be mounted on walls or ceilings. On flat or vaulted surfaces. Can be mounted with no gaps on existing ceilings or wall surfaces, suspended mounted on plasterboard or suspended directly from a track system.

    Light reflectance

    3 mm-39 mm: 90,0% per ASTM E147-98a.

    Fire safety classification

    3 mm-39 mm: Class A per ASTM E84; B s1d0 per ISO EN 13823.

    Cleaning and repair

    Can be vacuumed. Spots can be removed with water and sponge. Damaged surfaces can be repaired.

    Color selection

    Can be tinted in the entire NCS, RAL, Sherwin Williams or Benjamin Moore color scale.

    Environment

    3 mm-39 mm: 4 g/l (0,03 lbs/gal) VOC (emissions) per ASTM D3960, LEED.

    Climate

    Installation temperatures should be between 15 °C and 32 °C (60 °F and 90 °F) with humidity that does not exceed 70%. Tested for mold growth per ASTM D3273.

    Sound absorption

    25 mm: NRC 0.74 per ASTM C423. Alpha W 0,80 (class B) per ISO 354/ISO11654.

    39 mm: NRC 0.75-80 per ASTM C423. Alpha W 0,80–85,00 (class B) per ISO 354/ISO11654.

    Marble Hades

    Dimensions & weight

    3 mm: 3 mm (1/8 inch) thick. Weight (dry) 0.7 kg/m² (2,2 oz/ft²).

    25 mm: 28 mm (1,1 inch) total construction height. Weight (dry, excl. adhesive/mech. fasteners) 3.55 kg/m² (11,6 oz/ft²).

    39 mm: 42 mm (1,65 inch) total construction height. Weight (dry, excl. adhesive/mech. fasteners) 4.7 kg/m² (15,4 oz/ft²).

    Installation

    3 mm: Can be mounted on walls or ceilings. On flat or vaulted surfaces. On most absorbent surfaces, primer may sometimes be needed.

    25 mm-39 mm: Can be mounted on walls or ceilings. On flat or vaulted surfaces. Can be mounted with no gaps on existing ceilings or wall surfaces, suspended mounted on plasterboard or suspended directly from a track system.

    Light reflectance

    3 mm-39 mm: 90,0% per ASTM E1477-98a.

    Fire safety classification

    3 mm-39 mm: Class A per ASTM E84; B s1d0 per ISO EN 13823.

    Cleaning and repair

    Can be vacuumed. Spots can be removed with water and sponge. Damaged surfaces can be repaired.

    Environment

    3 mm-39 mm: 4 g/l (0,03 lbs/gal) VOC (emissions) per ASTM D3960, LEED.

    Climate

    Installation temperatures should be between 15 °C and 32 °C (60 °F and 90 °F) with humidity that does not exceed 70%. Tested for mold growth per ASTM D3273.

    Sound absorption

    25 mm: NRC 0.45-0.60 per ASTM C423. Alpha W 0,50 (class D)-0,55 (class D) per ISO 354/ISO11654.

    39 mm: NRC 0.50-0.60 per ASTM C423. Alpha W 0,55 (class D) per ISO 354/ISO11654.

      Free Sample for... Acoustic Plaster System London

      Fields marked with an * are required.

      For more details on how we handle your data, please view our Privacy Policy

        Apply For... Experienced Site Foreman

        Requirements

        Pacy & Wheatley Acoustics, one of the UK’s leading providers & installers of interior acoustic solutions, is looking for experienced Acoustic Installers & a Site Foreman to help deliver multiple projects in the South of England (London area) candidates location Yorkshire/ London.

        Specifications

        • Experience of managing & directing a team of installers, preferable.
        • Experience in Reporting systems planning and dealing with Clients representatives.
        • Experience & knowledge in acoustic installations (acoustic panels & spray applied render) not essential but must be willing work and train on products.
        • Suitable skills include drylining, tape & jointing, plastering, plaster spraying and high specification decoration finishes.
        • CSCS, SSTS & IPAF cards required. (if some not available training offered)
        • General work is Monday – Friday (10-hour day)
        • Suitable applicants will be rewarded with high rates on a self-employed basis/employed.
        • Must be willing to travel and lodge.

        Fields marked with an * are required.

        For more details on how we handle your data, please view our Privacy Policy

          Apply For... Acoustic Ceiling Installers

          Requirements

          Pacy & Wheatley Acoustics are looking for Experienced Operative/teams aswell as Operatives with no experience to assist installation of our Specialist sprayed seamless Acoustic ceilings.

          Experienced Operatives in application/site management of similar products in this area of sprayed acoustic systems are welcome and possible further opportunities to assist in development within the business.

          Non Experienced Operatives is all about desire and commitment to hard work and learning, Hungry Individuals with the will to work in a team and have the mentality to grow and be trained in our systems.

          Should have basic construction skills and desire to move forward and be part of a growing side of the Pacy & Wheatley Group long term.

          We are based in Doncaster however move around the country continually so location not that important however must be willing to travel and lodge.

          We are installers of Rockfon Mono Acoustic/Bospray a single sprayed coating to structural soffits and the Fade product as well as other products in our brand.

          Fields marked with an * are required.

          For more details on how we handle your data, please view our Privacy Policy

            Contact me regarding... Acoustic Plaster System London

            Fields marked with an * are required.

            For more details on how we handle your data, please view our Privacy Policy

              Access Our Downloads

              Fields marked with an * are required.

              For more details on how we handle your data, please view our Privacy Policy

                Contact Us Today

                Fields marked with an * are required.

                For more details on how we handle your data, please view our Privacy Policy